Wine Guardian Humidifier User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 19
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
Wine Guardian-Mounted (Integrated Installation)
NOTE: Integrated humidifiers can be mounted in either of the two side openings of the
cooling unit on the cooling or evaporator end only. Do not mount the humidifier on the
condenser end of the unit. If a duct connection is in that position, move the duct
connection to the top or other side.
1) Remove side access panel on the side of the cooling unit where you wish to mount the
humidifier.
2) Select the proper adapter plate for the cooling unit, (¼-, ½-, and 1-ton units use the same
adapter plate; 2-ton units require a larger adapter plate that must be ordered separately) and
install in the side opening using the screws from the panel removed above. The adapter plate
allows the humidifier to be mounted in either a forward position or back toward the center by
simply rotating the adapter plate 180 degrees.
3) Install a ½” flexible drain line from the bottom of the humidifier to an open drain or connect
into the drain line from the cooling unit.
4) Install a ¼” hot water line from the water supply into the opening on the top of the
humidifier. A shut off valve (not provided) is recommended to isolate the humidifier from
the water system when needed.
Integrated Humidifier Cut-Away Drawing
Figure 6.0
Mounting the Humidistat
Each Wine Guardian Humidifier comes with a humidistat and 25 feet of humidistat cable pre-
wired to unit. The unit also comes with 5 feet of 3-wire, 24-volt power cable that connects to the
terminal on the side strip of the Wine Guardian Unit. (See Step 3 next page.) If you need to
remove the wires, please note the color-coding and replace the wires in the correct location.
After the wires are re-installed, test with a slight pulling motion back on the wire. If additional
wiring is needed, it can be spliced onto the factory-furnished wire. Be sure to match colors for
continuity and to insulate each wire separately with electrical tape.