Wine Guardian Through-the-Wall Specifications Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 47
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
29
Installation of the Optional Wine Guardian
Remote Sensor
The Remote Sensor is a combination temperature and humidity
sensor only. It is designed to be mounted within the wine cellar
and can be used in combination with Local Interface Controller or
the Remote Interface Controller and up to two additional Remote
Sensors to control multiple areas within the wine cellar.
Mounting the Remote Sensor
Fig.1
1. Disconnect the communication cable from the back the
remote sensor. Install the communication cable within
the wall and/or ceiling structure of the wine cellar to the
desired controller mounting location.
2. Mount the Remote Sensor on a solid surface away from
doors, corners, air outlets, drafts or heat generating
equipment. Do not mount the Remote Sensor directly on
an outside wall or wall adjacent to a boiler room. Use a
piece of foam insulation behind the sensor to insulate it
from a hot or cold surface. The recommended height is
4 to 5 feet above the finished floor.
3. Remove the sensor cover plate by removing the two
allen head screws at the top of the cover using the allen
head wrench provided in the kit.(Fig.2) Mark the
mounting points at the desired location within the wine
cellar. Also mark the location of the communication
cable connection as this area will require sufficient
clearance, for instance 1½” hole in the wall for flush
mounting of the sensor plate.
Fig.1
Important
A splitter device has been supplied within the Remote
Sensor kit. The splitter device must be mounted at the
WG unit.. DO NOT mount the splitter device at the back
of the Remote Interface Controller or to the back of the
Remote Sensor as this WILL cause component or system
damage.
Fig, 2